CyFlow™ CD11a FITC

CyFlow™ CD11a FITC
Antigen: CD11a
Alternative Name: LFA-1
Clone: MEM-25
Application: Flow cytometry
Format/Fluorochrome: FITC
Laser: Blue
Target Species: Human
Field of Interest: Immunophenotyping
Species of Origin: Mouse
Regulatory Status: RUO
Clonality: monoclonal
Emission Maximum: 518 nm
Excitation Maximum: 490 to 495 nm
Isotype: IgG1
Order number: BD356093

For Research Use Only
Not for use in diagnostic or therapeutic procedures.

Quantity 100 tests Volume 2 ml Immunogen Leukocytes of a patient suffering from... more
CyFlow™ CD11a FITC
Quantity100 tests
Volume2 ml
ImmunogenLeukocytes of a patient suffering from LGL-type Leukemia
SpecifityThe mouse monoclonal antibody MEM-25 recognizes CD11a antigen, a 170-180 kDa type I transmembrane glycoprotein expressed on B and T lymphocytes, monocytes, macrophages, neutrophils, basophils and eosinophils.
Background InformationCD11a (LFA-1 α) together with CD18 constitute leukocyte function-associated antigen 1 (LFA-1), the αLβ2 integrin. CD11a is implicated in activation of LFA-1 complex. LFA-1 is expressed on the plasma membrane of leukocytes in a low-affinity conformation. Cell stimulation by chemokines or other signals leads to induction the high-affinity conformation, which supports tight binding of LFA-1 to its ligands, the intercellular adhesion molecules ICAM-1, -2, -3. LFA-1 is thus involved in interaction of various immune cells and in their tissue-specific settlement, but participates also in control of cell differentiation and proliferation and of T-cell effector functions. Blocking of LFA-1 function by specific antibodies or small molecules has become an important therapeutic approach in treatment of multiple inflammatory diseases. For example, humanized anti-LFA-1 antibody Efalizumab (Raptiva) is being used to interfere with T cell migration to sites of inflammation; binding of cholesterol-lowering drug simvastatin to CD11a allosteric site leads to immunomodulation and increase in lymphocytic cholinergic activity.
UsageThe reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 20·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (2 ml) is sufficient for 100 tests.
Storage BufferThe reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.1% (w/v) sodium azide.
StorageAvoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
StabilityDo not use after expiration date stamped on vial label.